Overview
Converts Spea ICT 3030 in-circuit test result files to WATS UUT reports.
and any integration-specific context not covered by the README. -->
Integration Details
| Property | Value |
|---|---|
| Category | WATS Client converter |
| Type | FileConverter |
| Format | TXT |
| Test type | ICT |
File Format Assumptions and Requirements
Examples: encoding (UTF-8/ASCII), line endings, required vs optional fields, field order constraints, supported file version(s) -->
- Input encoding: UTF-8
Hardcoded Values and Defaults
Converter Parameters
These parameters are configured in the WATS Client Configurator converter arguments.
| Parameter | Default Value |
|---|---|
R |
Resistors |
RP |
Resistors |
RS |
Resistors |
C |
Capacitors |
CS |
Capacitors |
CP |
Capacitors |
DSC |
Capacitors |
L |
Inductors |
D |
Diodes |
Q |
Transistors |
CON |
Connectors |
SHO |
Short |
TC |
Thermocouple |
PTC |
PTC |
DZ |
ZenerDiodes |
F |
Fuses |
J |
Jumpers |
T |
Transformers |
ISO |
Isolators |
U |
ICs |
| Parameter | Default | Effect |
|---|---|---|
R |
Resistors |
|
RP |
Resistors |
|
RS |
Resistors |
|
C |
Capacitors |
|
CS |
Capacitors |
|
CP |
Capacitors |
|
DSC |
Capacitors |
|
L |
Inductors |
|
D |
Diodes |
|
Q |
Transistors |
|
CON |
Connectors |
|
SHO |
Short |
|
TC |
Thermocouple |
|
PTC |
PTC |
|
DZ |
ZenerDiodes |
|
F |
Fuses |
|
J |
Jumpers |
|
T |
Transformers |
|
ISO |
Isolators |
|
U |
ICs |
Input Record Types and Regex Patterns
The converter uses TextConverterBase.SearchFields to match lines. Each entry below is one regex field registration with the associated capture groups.
Header field: UUTField.UseSubFields (parsed in InHeader state)
| Capture Group | Type | Maps to WATS Field |
|---|---|---|
Seq |
string |
UUTField.SequenceName |
SeqVer |
string |
UUTField.SequenceVersion |
Oper |
string |
UUTField.Operator |
StartDate |
DateTime |
used in ProcessMatchedLine |
StartTime |
TimeSpan |
used in ProcessMatchedLine |
Record: Measure (parsed in InTest state)
| Capture Group | Type | Maps to WATS Field |
|---|---|---|
Date |
DateTime |
used in ProcessMatchedLine |
Time |
TimeSpan |
used in ProcessMatchedLine |
Record: Footer (parsed in InTest state)
| Capture Group | Type | Maps to WATS Field |
|---|---|---|
Date |
DateTime |
used in ProcessMatchedLine |
Time |
TimeSpan |
used in ProcessMatchedLine |
Known Limitations and Edge Cases
that operators should be aware of -->
Configuration Guidance
Parameters are configured in the WATS Client Configurator under the converter's Arguments XML. Example:
<Arguments>
<!-- TODO: paste a real example Arguments XML block here -->
</Arguments>
Getting Started
Download
The recommended installation method is via the MSI installer. Download the latest release from the Releases page.
Installation
Using the MSI Installer (Recommended)
- Download the
.msifile from the Releases page. - Run the installer - it will automatically place the converter in the correct WATS Client folder.
- Restart the WATS Client Service.
Comments